Specifications: (See all)
Transient overvoltage
Impulse withstand (overvoltage); Category II of IEC 60364-4-443
AC accuracy, closed loop with 6105A
To 140 ppm
Calibration Documentation
Report of calibration with data included; 17025 accredited report optional
Output ranges
2 A, 20 A, 120 A (100 A dc)
Warm up Time
1 hour
Description

The 52120A is designed for users whose ability to address their calibration workload may be
limited by the output current, accuracy and drive capability of their present test equipment,
including:
  • Calibration professionals in a calibration/standards lab or an electrical utility
  • Manufacturers of power/energy instrumentation and meters, power quality analyzers or power converters
  • Users of electrical test and measurement equipment

The 52120A operates as a transconductance amplifier with:

  • 5522A/5502A/5520A/5500A Multi-Product Calibrators
  • 5730A*/5700A/5720A Multifunction Calibrator
  • 6105A*/6100B* Electrical Power Standard
  • 5080A Multi-Product Calibrator
  • 9100 Universal Calibration System
  • Any calibrator, signal generator or power supply capable of sourcing 2 V or 200 mA, dc or ac
*Special closed-loop operating mode

You may also operate your 52120A in closed-loop mode, seamlessly communicating with your Fluke Calibration 6105A or 6100B Electrical Power Standard to deliver enhanced 52120A accuracy.

Specifications
Operating limits
Output ranges
2 A, 20 A, 120 A (100 A dc)
Input current range
200 mA, 200 mA, 120 mA (100 mA dc)
Current gain
10, 100, 1000
Input voltage range
2 V, 2 V, 1.2 V (1.0 V dc)
Transconductance
1,10,100 Siemens
Frequency
To 10 kHz
Maximum output compliance voltage
4.5 Vrms (6.4 Vpeak)
Inductive drive capability
1 mH load
Output isolation, current terminal to earth
600 Vrms, 850 Vpeak, dc to 850 Hz
Performance specifications
AC accuracy, closed loop with 6105A
To 140 ppm
DC accuracy, standalone
To 160 ppm
AC accuracy, standalone
To 350 ppm
Phase angle accuracy
0.006°
Load dependent phase angle shift
<0.001° @ 60 Hz
General Specifications
Transient overvoltage
Impulse withstand (overvoltage); Category II of IEC 60364-4-443
Warm up Time
1 hour
Temperature Performance
Operating temperature 5 °C to 35 °C / Calibration temperature range 16 °C to 30 °C
Relative Humidity
<80 % 5 °C to 31 °C ramping linearly down to 50 % at 35 °C
Altitude
0 m to 2,500 m
Safety
MIL-PRF-28800F class 3
Line Power
100 V to 240 V with up to ±10 % fluctuations
Power Consumption
< 1500 VA
Dimensions
192 mm x 432 mm x 645 mm
Weight (without options)
25 kg
Specifications confidence level
99 %
Related documentation
Calibration Documentation
Report of calibration with data included; 17025 accredited report optional
Reviews
0 / 5
average product rating
0
0
0
0
0

There are no reviews for this product, be the first to leave your review.

Answers & questions

No questions about this product, be the first and ask your question.

Fluke 52120A Transconductance Amplifier
0.00€
Модули для Opencart