Fluke 1504 Tweener Thermometer Readout

All about product
Specification
Reviews
0
Questions
0
Pre-Order
Product Code: 1504
Reviews: 0
2 989.00€
Ex Tax: 2 989.00€
Specifications: (See all)
Dimensions
61 x 143 x 181mm
Temperature Range
Any thermistor range
Working temperature
13 °C to 33 °C
Weight
1.0 kg
Probe
Thermistors
Description

1502A Tweener PRT Readout

The Fluke 1502A Tweener (formerly Hart Scientific) features accuracy up to ±0.006 °C (the 1504 is even more accurate, up to ±0.002 °C). In addition, it reads 100-ohm, 25-ohm, and 10-ohm probes, has a resolution of 0.001 °C across its entire range, and is the smallest unit in its class.

Each Tweener is programmable to match a probe’s constants for maximum linearity and accuracy. All probe constants and coefficients are programmed through simple, front-panel keystrokes. Temperature is displayed in °C, °F, K, or resistance in ohms.

The 1502A accurately measures the resistance of the probe and then converts the resistance to a temperature value using its built-in algorithms.

For convenience, the 1502A reads the common industrial grade IEC-751 or “385 ALPHA RTD without any programming. Enter the actual R0 and ALPHA of the individual probe for increased accuracy. For maximum accuracy, use the ITS-90 formulas. The Tweener accepts the subranges 4 and 6 through 11.

ITS-90 formulas reside in the Tweener’s firmware. If your probe has been calibrated for any of the above subranges of the ITS-90, you simply enter the coefficients directly into your Tweener.

Each thermometer comes complete with an RS-232 interface for automation of temperature data collection, calibrations, or process control functions. An IEEE-488 interface is available as an option.

The 1502A is calibrated digitally using the front-panel buttons. You never have to open the box to calibrate it. This calibration protocol further reduces the cost of the 1502A. It goes where you go and works the way you want it to.

1504 Tweener Thermistor Readout

If you need more accuracy in a limited temperature range, the Model 1504 Tweener gives it to you as a thermistor readout. Thermistors are less fragile than PRTs and less likely to be impacted by mechanical shock. Thermistors are more sensitive to temperature, have faster response times, and come in many shapes for different applications.

Typical accuracy of a 1504 is ±0.002 °C with a resolution of 0.0001 °C.

Software

With our 9934 LogWare, both Tweener models may be used for real-time data acquisition. Collect data and analyze it graphically or statistically. Additionally, Tweeners may be used as reference thermometers with our MET/TEMP II software.

Calibration choices

Each Tweener and its accompanying probe (sold separately) have their own individual calibration reports. Overall system error can be calculated from the individual errors, rendering the added cost of system data unnecessary. However, for those requiring it, system data is available at two or more temperatures of your choice. (See Calibration Model 1929-X )

Specifications
Technical data
Display resolution
8-digit, 7-segment, yellow-green LED; 0.5-inch-high characters
General characteristics of thermometers
Computer communications
RS-232 serial standard IEEE-488 (GPIB) optional
Technical Specifications
Temperature Range
Any thermistor range
Probe
Thermistors
Resistance
0 Ω to 1 MΩ, auto-ranging
Characterizations
Steinhart-Hart thermistor polynomial Callendar-Van Dusen: R0, a, d, and b
Resistance Accuracy
0 Ω to 5 KΩ: 0.5 Ω 5 KΩ to 200 KΩ: 100 ppm 200 KΩ to 1 MΩ: 300 ppm
Temperature Accuracy
±0.002 °C at 0 °C ±0.002 °C at 25 °C ±0.004 °C at 50 °C ±0.010 °C at 75 °C ±0.020 °C at 100 °C (Using 10 KΩ thermistor sensor, a=0.04. Does not include probe uncertainty or characterization errors.)
Resistance Resolution
0 Ω to 10 KΩ: 0.01 Ω 10 KΩ to 100 KΩ: 0.1 Ω 100 KΩ to 1 MΩ: 1 Ω
Temperature Resolution
0.0001 °C
Excitation Current
2 and 10 µA, automatically selected
Measurement Period
1 second
Digital Filter
Exponential, 0 to 60 seconds time constant (user selectable)
Probe Connection
4-wire with shield, 5-pin DIN connector
General parameters
Dimensions
61 x 143 x 181mm
Weight
1.0 kg
Power supply
230 VAC (±10 %), 50/60 Hz, 1 A, nominal, specify
Environmental parameters
Working temperature
13 °C to 33 °C
Reviews
0 / 5
average product rating
0
0
0
0
0

There are no reviews for this product, be the first to leave your review.

Answers & questions

No questions about this product, be the first and ask your question.

Fluke 1504 Tweener Thermometer Readout
2 989.00€
Модули для Opencart