Why IONIVAC?

Our IONIVAC gauges series, whether passive (IE) or active (ITR) offers the ability to measure into ultra high vacuum. This enables detailed tracking of experiments, and control of the variables in processes. 


IONIVAC hot cathode gauges work by having a hot cathode emit electrons which impinge on an anode. The measured gas is thus ionized. The resulting positive ion current is detected through the third electrode and this current is used as the signal which is proportional to the pressure. 


The hot cathode ionization sensors offer a wide measurement range of 10-12 to 10-1 mbar (0.75·10-10 to 0.75·10-1 Torr) depending on the type of hot cathode technology used.


IONIVAC ITR 90/200 series

Optimized combination transmitter


The IONIVAC ITR is an optimized combination transmitter. The combination of a hot cathode ionisation sensor (utilising the Bayard Alpert method of hot cathode ionisation) and a Pirani sensor enables vacuum pressure measurements from 5 . 10-10 to 1000 mbar (3.75 . 10-10 to 750 torr). 


Two main variants are available:


ITR 90 with single hot cathode filament

ITR 200 with dual filaments to increase the lifespan via inbuilt redundancy. It will automatically switch filaments in the event of failure and indicate that a filament has failed. To further increase the gauge life, it is possible to run a degas program which can re-invigorate the filaments performance. 

Continuous pressure measurements from 1 . 10-10 mbar/torr to atmospheric pressure  

Compact design with exchangeable cathodes and degas mode 

Bakeable sensor to enable UHV measurement 

Analogue, display, digital, and profibus interfaces available for simple install 

High repeatability within the typical process pressure range of 10-2 to 10-9 mbar  

Precise UHV pressure measurements with passive gauging, enabling measurement down to 10-12 mbar/torr  

Specifications
Main characteristics
Specifications
Full specifications are provided in the document, which can be downloaded from the DataSheet tab.
Reviews
0 / 5
average product rating
0
0
0
0
0

There are no reviews for this product, be the first to leave your review.

Answers & questions

No questions about this product, be the first and ask your question.

Leybold IONIVAC Hot cathode Bayard Alpert
0.00€
Модули для Opencart