Quantity
|
Cost
|
||
|
|
|||
|
|
|||
The Optris Xi 1M is a rugged, short-wavelength fixed-mount
designed for non-contact temperature measurement of hot, low-emissivity materials. By operating within a spectral range of 0.85 to 1.1 µm, the infrared camera for alloys, metals, ceramics, and semiconductors effectively minimizes measurement deviations caused by reflections and emissivity changes, which are common in high-temperature environments.
The Xi 1M of the Xi series measures temperatures from 450 to 1800 °C without sub-range switching. Its CMOS detector provides 396 × 300 pixels with a 15 µm pixel pitch. Furthermore, the thermal camera records full-frame images at 20 Hz and supports line scanning at speeds up to 500 Hz. In this mode, 396 × 8 pixels via Ethernet or 396 × 1 pixels in smart operation enable temperature profiling of moving targets, such as metal strips or rotating parts.
To ensure consistent image sharpness, the Xi 1M features a motorized focus that allows precise focusing at different working distances. Moreover, its IP67-rated stainless steel housing protects the lens and electronics even under demanding industrial conditions. The infrared camera also offers Ethernet, USB 2.0, and RS-485 interfaces. Additionally, it supports Power-over-Ethernet and operates on an 8–30 V DC supply, simplifying integration into existing systems.
For automation tasks, the Xi 1M provides one analog output and one isolated input. When needed, optional process interface modules can add up to three analog or alarm outputs each or industrial fieldbus communication. Furthermore, up to three stackable interfaces can be combined, offering a total of nine independent analog or relay outputs with integrated fail-safe monitoring.
Because of its autonomous operating capability, the thermal camera can perform internal temperature processing and hotspot detection without a computer. The thermal imager directly outputs results as analog, digital, or alarm signals.
Xi 1M - Infrared Camera for Alloys & Metals - Important Features:
- Industrial Ethernet short-wavelength infrared camera
- Wide measurement range from 450°C to 1800°C without sub-ranges
- Small-sized, ruggedized with motorized focus
- Fast line scanning mode with 500 Hz (Ethernet: 396 x 8 px / autonomous: 396 x 1 px)
- Autonomous operation with auto hot spot finder, direct analog or alarm output, and various fieldbus communication options
-
MODEL Xi 1M ETH 50° x 38° Xi 1M ETH 7° x 5° Xi 1M ETH 14° x 10° Xi 1M ETH 28° x 21° DETECTOR Optical resolution 396x300 pixels 396x300 pixels 396x300 pixels 396x300 pixels Pixel pitch 15 µm 15 µm 15 µm 15 µm Detector CMOS CMOS CMOS CMOS Spectral Range 0.85 - 1.1 µm 0.85 - 1.1 µm 0.85 - 1.1 µm 0.85 - 1.1 µm Optical Filter No No No No Frame rate Full resolution: 20 Hz (Ethernet) **1)
Subframe mode: 20 Hz (USB, autonomous) **1)
Linescan: 500 Hz (Ethernet, autonomous) **1)
Full resolution: 20 Hz (Ethernet) **1)
Subframe mode: 20 Hz (USB, autonomous) **1)
Linescan: 500 Hz (Ethernet, autonomous) **1)
Full resolution: 20 Hz (Ethernet) **1)
Subframe mode: 20 Hz (USB, autonomous) **1)
Linescan: 500 Hz (Ethernet, autonomous) **1)
Full resolution: 20 Hz (Ethernet) **1)
Subframe mode: 20 Hz (USB, autonomous) **1)
Linescan: 500 Hz (Ethernet, autonomous) **1)
OPTICAL Field of View 50° x 38° 7° x 5° 14° x 10° 28° x 21° Focal length [mm] 7.0 50.0 25.0 12.0 F Number 2.0 2.8 1.8 2.0 Distance to Spot Ratio (D:S) 105:1 806:1 401:1 195:1 Minimum Distance to target 300 mm 800 mm | 400 mm 300 mm 300 mm Interchangeable optics No No No No MEASUREMENT Object Measurement Range 450 – 1800 °C 525 – 1800 °C 450 – 1800 °C 450 – 1800 °C Accuracy For object temperature < 1400 °C: ±1 % of reading
For object temperature < 1600 °C: ±2 % of reading
For object temperature < 1400 °C: ±1 % of reading
For object temperature < 1600 °C: ±2 % of reading
For object temperature < 1400 °C: ±1 % of reading
For object temperature < 1600 °C: ±2 % of reading
For object temperature < 1400 °C: ±1 % of reading
For object temperature < 1600 °C: ±2 % of reading
Thermal Sensitivity (NETD) < 2 K (< 900 °C) / < 4 K (< 1400 °C) < 2 K (< 900 °C) / < 4 K (< 1400 °C) < 2 K (< 900 °C) / < 4 K (< 1400 °C) < 2 K (< 900 °C) / < 4 K (< 1400 °C) Smallest detectable Spot Size IFOV: 1 pixel 0.7 mm 0.3 mm | 0.1 mm 0.5 mm 0.7 mm Smallest measurable Spot Size MFOV 2.96 mm 1.2 mm | 0.4 mm 2.5 mm 2.8 mm MFOV Measurement Field of View 4x4 pixels 4x4 pixels 4x4 pixels 4x4 pixels Warm-up time 10 min 10 min 10 min 10 min Emissivity /Transmissivity/ Reflectivity adjustable: 0.100…1.100 adjustable: 0.100…1.100 adjustable: 0.100…1.100 adjustable: 0.100…1.100 INTERFACES Interface USB 2.0 / Ethernet (100 Mbit/s) / PoE / RS 485 **2) USB 2.0 / Ethernet (100 Mbit/s) / PoE / RS 485 **2) USB 2.0 / Ethernet (100 Mbit/s) / PoE / RS 485 **2) USB 2.0 / Ethernet (100 Mbit/s) / PoE / RS 485 **2) Supported Protocols USB, Ethernet (Static), RS485 **2), Serial Communication Optional: EtherNet/IP, Profinet, Modbus TCP, Ethernet TCP USB, Ethernet (Static), RS485 **2), Serial Communication Optional: EtherNet/IP, Profinet, Modbus TCP, Ethernet TCP USB, Ethernet (Static), RS485 **2), Serial Communication Optional: EtherNet/IP, Profinet, Modbus TCP, Ethernet TCP USB, Ethernet (Static), RS485 **2), Serial Communication Optional: EtherNet/IP, Profinet, Modbus TCP, Ethernet TCP Compatible Software PIX Connect, EasyComm, ConnectSDK, EasyAPI, DirectSDK PIX Connect, EasyComm, ConnectSDK, EasyAPI, DirectSDK PIX Connect, EasyComm, ConnectSDK, EasyAPI, DirectSDK PIX Connect, EasyComm, ConnectSDK, EasyAPI, DirectSDK ANALOG INPUT/OUTPUT Direct output/input 1x input (analog or digital)
1x analog output (0/4–20 mA)
electrically isolated
1x input (analog or digital)
1x analog output (0/4–20 mA)
electrically isolated
1x input (analog or digital)
1x analog output (0/4–20 mA)
electrically isolated
1x input (analog or digital)
1x analog output (0/4–20 mA)
electrically isolated
Optional Industrial Process interface (PIF) 3x analog outputs (0/4–20 mA or 0–10 V)
3x alarm outputs (relais, 0–30 V / 400 mA)
3x inputs (analog or digital)
1x fail-safe (LED and relay)
stackable up to 3 PIFs, electrically isolated
3x analog outputs (0/4–20 mA or 0–10 V)
3x alarm outputs (relais, 0–30 V / 400 mA)
3x inputs (analog or digital)
1x fail-safe (LED and relay)
stackable up to 3 PIFs, electrically isolated
3x analog outputs (0/4–20 mA or 0–10 V)
3x alarm outputs (relais, 0–30 V / 400 mA)
3x inputs (analog or digital)
1x fail-safe (LED and relay)
stackable up to 3 PIFs, electrically isolated
3x analog outputs (0/4–20 mA or 0–10 V)
3x alarm outputs (relais, 0–30 V / 400 mA)
3x inputs (analog or digital)
1x fail-safe (LED and relay)
stackable up to 3 PIFs, electrically isolated
Cable length Ethernet / RS485: 1 m (standard), 5 m, 10 m, 20 m (extendable up to 100 m)
USB: 1 m (standard), 3 m, 5 m
Ethernet / RS485: 1 m (standard), 5 m, 10 m, 20 m (extendable up to 100 m)
USB: 1 m (standard), 3 m, 5 m
Ethernet / RS485: 1 m (standard), 5 m, 10 m, 20 m (extendable up to 100 m)
USB: 1 m (standard), 3 m, 5 m
Ethernet / RS485: 1 m (standard), 5 m, 10 m, 20 m (extendable up to 100 m)
USB: 1 m (standard), 3 m, 5 m
IMAGE PROCESSING Configuration via PIX Connect via PIX Connect via PIX Connect via PIX Connect Operation Autonomous Standalone and/or computer-enabled Autonomous Standalone and/or computer-enabled Autonomous Standalone and/or computer-enabled Autonomous Standalone and/or computer-enabled Capabilities Measurement of hot metal surfaces and molten metal, Autonomous temperature evaluation of areas of interest, Linescanner, EventGrabber, Merger, Alarming, Comparison Functions Measurement of hot metal surfaces and molten metal, Autonomous temperature evaluation of areas of interest, Linescanner, EventGrabber, Merger, Alarming, Comparison Functions Measurement of hot metal surfaces and molten metal, Autonomous temperature evaluation of areas of interest, Linescanner, EventGrabber, Merger, Alarming, Comparison Functions Measurement of hot metal surfaces and molten metal, Autonomous temperature evaluation of areas of interest, Linescanner, EventGrabber, Merger, Alarming, Comparison Functions GENERAL Size Ø 36 mm x 112-127 mm (depending on lens), thread: M30x1 Ø 36 mm x 112-127 mm (depending on lens), thread: M30x1 Ø 36 mm x 112-127 mm (depending on lens), thread: M30x1 Ø 36 mm x 112-127 mm (depending on lens), thread: M30x1 Housing Material Stainless steel Stainless steel Stainless steel Stainless steel Weight 270 g (without mounting bracket) 270 g (without mounting bracket) 270 g (without mounting bracket) 270 g (without mounting bracket) Tripod 1/4-20 UNC 1/4-20 UNC 1/4-20 UNC 1/4-20 UNC Focus Motorized Motorized Motorized Motorized Country of Origin Germany Germany Germany Germany ENVIRONMENTAL & CERTIFICATIONS Operating Temperature Range 5...50 °C 5...50 °C 5...50 °C 5...50 °C Storage Temperature Range -40...70 °C -40...70 °C -40...70 °C -40...70 °C Relative humidity 10 – 95 %, non-condensing 10 – 95 %, non-condensing 10 – 95 %, non-condensing 10 – 95 %, non-condensing Protection Class IP67, NEMA-4 IP67, NEMA-4 IP67, NEMA-4 IP67, NEMA-4 EMC 2014/30/EU 2014/30/EU 2014/30/EU 2014/30/EU Shock IEC 60068-2-27 (25 G and 50 G) IEC 60068-2-27 (25 G and 50 G) IEC 60068-2-27 (25 G and 50 G) IEC 60068-2-27 (25 G and 50 G) Vibration IEC 60068-2-6 (sinus shaped), IEC 60068-2-64 (broadband noise) IEC 60068-2-6 (sinus shaped), IEC 60068-2-64 (broadband noise) IEC 60068-2-6 (sinus shaped), IEC 60068-2-64 (broadband noise) IEC 60068-2-6 (sinus shaped), IEC 60068-2-64 (broadband noise) Standards CE, UKCA, RoHS CE, UKCA, RoHS CE, UKCA, RoHS CE, UKCA, RoHS POWER Power Supply 8-30 VDC, USB, Power over Ethernet (PoE) 8-30 VDC, USB, Power over Ethernet (PoE) 8-30 VDC, USB, Power over Ethernet (PoE) 8-30 VDC, USB, Power over Ethernet (PoE) Power Consumption max. 2.5 W max. 2.5 W max. 2.5 W max. 2.5 W Part number OPTXI1MO7SFT180 | OPTXI1MO7CFT180 OPTXI1MO14T180 OPTXI1MO28T180 Additional Remarks 1) Start-up temperature range for variant with focal length of 50 mm is increased to 525°C for 20 Hz and 575°C for 500 Hz modes
2) Direct out- and inputs are not available while using the RS485 interface
1) Start-up temperature range for variant with focal length of 50 mm is increased to 525°C for 20 Hz and 575°C for 500 Hz modes
2) Direct out- and inputs are not available while using the RS485 interface
1) Start-up temperature range for variant with focal length of 50 mm is increased to 525°C for 20 Hz and 575°C for 500 Hz modes
2) Direct out- and inputs are not available while using the RS485 interface
1) Start-up temperature range for variant with focal length of 50 mm is increased to 525°C for 20 Hz and 575°C for 500 Hz modes
2) Direct out- and inputs are not available while using the RS485 interface