Quantity
|
Cost
|
||
|
|
|||
|
|
|||
The SP-MGTP(MGT Pump) is a sampling type gas detector that measures six(6) major gases simultaneously, which cause most of the industrial accidents, to protect workers from the disasters caused by the Oxygen deficiency, Toxic gas poisoning and gas explosion.
It detect up to 6 gases with 37 different toxic and flammable gas combinations and displays their concentrations and raises an alarm(visual, vibrating, and audible) when the risk occurs.
KEY FEATURE
-
Sampling type with embedded pump & Probe
-
Max 6 gas with 37 different gas combinations
-
Event log (Recent 30 event / bump / calibration)
-
Easy to maintain (2 filters in probe & in detector)
-
Inner teflon coating of gas tube line
-
IrDA communication
-
Single Docking Station
Product Specifications
| Model | SP-MGTP |
|---|---|
| Display | LCD display with backlight for clear visibility in various lighting conditions Indicator LEDs for status and alarm notifications |
| Keys | 3 operational and programming keys for intuitive navigation and setup |
| Sensors | Electrochemical Sensors: For toxic gases and oxygen (O₂) detection PID (Photoionization Detector): For precise VOC (Volatile Organic Compound) detection Catalytic Sensors: For combustible gas detection NDIR (Non-Dispersive Infrared) Sensors: For monitoring combustible gases |
| Alarms | Visual: LCD alarm display with backlight and indicator LEDs for clear alerts Audible: 90 dB buzzer at 10 cm for immediate sound warnings Vibration: Vibration alert for hazardous gas detection |
| Dimensions | 77 mm (W) x 146 mm (H) x 43 mm (D) |
| Weight | 490 g |
| Mounting Method | Integrated belt clip for easy attachment and hands-free use |
| Operating Temperature Range | -20°C to +50°C |
| Operating Humidity Range | 10% to 90% RH (Non-condensing) |
| IP Rating | IP67 (Fully dustproof and water-resistant for enhanced durability in harsh environments) |
| Environment Pressure Range | 80 kPa to 120 kPa (Suitable for use in environments with this pressure range) |
| Sampling Type | Built-in pump for efficient and accurate gas sampling *Sampling Distance: 25m |
| Battery Type | Rechargeable Li-ion power supply (4,000 mAh) for extended operational time |
| Operating Time | SP-MGTP-P0 Series: Approximately 30 hours of continuous use SP-MGTP-N0/N1/N2 Series: Up to 5 days or more, depending on usage and settings |
| Enclosure Material | TPU-coated polycarbonate (PC) for enhanced durability in tough conditions |
| IR-Link | For seamless data management and easy configuration |
| Flow Rate | 250 to 300 cc/min for consistent and accurate gas sampling |
| Maximum Length of Sampling Hose | 23m (75ft) |
| Warranty | 2 years from the date of purchase |
Sensor Specifications
Sensor Configuration
The SP-MGTP is equipped with four sensor slots, providing versatile and customizable gas detection capabilities. This modular design allows for the combination of different gas sensors to meet specific monitoring requirements. Below is a detailed list of the available sensors for each slot, enabling a wide range of configurations tailored to diverse industrial and safety applications.
| Model Name | Slot 1 (Fixed) | Slot 2 (Fixed) | Slot 3 (Optional Gas 1) | Slot 4 (Optional Gas 2) |
|---|---|---|---|---|
| SP-MGTP-P-4 | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | - |
| SP-MGTP-P-5-PID | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | PID (VOC Detection) |
| SP-MGTP-P-5-SO₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | SO₂ (Sulfur Dioxide) |
| SP-MGTP-P-5-Cl₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | Cl₂ (Chlorine) |
| SP-MGTP-P-5-NH₃ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | NH₃ (Ammonia) |
| SP-MGTP-P-5-H₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | H₂ (Hydrogen) |
| SP-MGTP-P-5-NO₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | NO₂ (Nitrogen Dioxide) |
| SP-MGTP-P-5-HF | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | HF (Hydrogen Fluoride) |
| SP-MGTP-P-5-HCN | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | HCN (Hydrogen Cyanide) |
| SP-MGTP-P-5-HCl | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | HCl (Hydrochloric Acid) |
| SP-MGTP-P-5-NO | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | NO (Nitric Oxide) |
| SP-MGTP-P-5-H₂O₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (Catalytic) | H₂O₂ (Hydrogen Peroxide) |
| SP-MGTP-N-4 | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | - |
| SP-MGTP-N-5-PID | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | PID (VOC Detection) |
| SP-MGTP-N-5-SO₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | SO₂ (Sulfur Dioxide) |
| SP-MGTP-N-5-Cl₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | Cl₂ (Chlorine) |
| SP-MGTP-N-5-NH₃ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | NH₃ (Ammonia) |
| SP-MGTP-N-5-H₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | H₂ (Hydrogen) |
| SP-MGTP-N-5-NO₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | NO₂ (Nitrogen Dioxide) |
| SP-MGTP-N-5-HF | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | HF (Hydrogen Fluoride) |
| SP-MGTP-N-5-HCN | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | HCN (Hydrogen Cyanide) |
| SP-MGTP-N-5-HCl | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | HCl (Hydrochloric Acid) |
| SP-MGTP-N-5-NO | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | NO (Nitric Oxide) |
| SP-MGTP-N-5-H₂O₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CH₄ (IR) | H₂O₂ (Hydrogen Peroxide) |
| SP-MGTP-N-5-CO₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | - |
| SP-MGTP-N-6-PID | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | PID (VOC Detection) |
| SP-MGTP-N-6-SO₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | SO₂ (Sulfur Dioxide) |
| SP-MGTP-N-6-Cl₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | Cl₂ (Chlorine) |
| SP-MGTP-N-6-NH₃ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | NH₃ (Ammonia) |
| SP-MGTP-N-6-H₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | H₂ (Hydrogen) |
| SP-MGTP-N-6-NO₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | NO₂ (Nitrogen Dioxide) |
| SP-MGTP-N-6-HF | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | HF (Hydrogen Fluoride) |
| SP-MGTP-N-6-HCN | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | HCN (Hydrogen Cyanide) |
| SP-MGTP-N-6-HCl | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | HCl (Hydrochloric Acid) |
| SP-MGTP-N-6-NO | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | NO (Nitric Oxide) |
| SP-MGTP-N-6-H₂O₂ | O₂ (Oxygen) | CO (Carbon Monoxide) + H₂S (Hydrogen Sulfide) | CO₂ (IR) + CH₄ (IR) | H₂O₂ (Hydrogen Peroxide) |
Applicable Sensor Specifications
The SP-MGTP ioffers a wide range of gas sensors, each designed to meet specific detection needs across various environments. Each sensor is engineered with distinct measuring ranges, resolutions, and alarm thresholds to provide reliable and accurate detection. Below are the specifications for the available sensors:
| Gas | Sensor Type | Measuring Range | Resolution | Low Alarm | High Alarm |
|---|---|---|---|---|---|
| Oxygen (O₂) | Electrochemical | 0 ~ 30 %vol | 0.1 %vol | 19 %vol | 23 %vol |
| Carbon Monoxide (CO) | Electrochemical | 0 ~ 1000 ppm | 1 ppm | 30 ppm | 60 ppm |
| Hydrogen Sulfide (H₂S) | Electrochemical | 0 ~ 200 ppm | 0.1 ppm | 10 ppm | 15 ppm |
| Methane (CH₄) | Catalytic / NDIR | 0 ~ 100 %LEL | 1 %LEL | 10 %LEL | 30 %LEL |
| Carbon Dioxide (CO₂) | Non-Dispersive Infrared (NDIR) | 0 ~ 5 %vol | 0.01 %vol | 0.5 %vol | 1.0 %vol |
| Ammonia (NH₃) | Electrochemical | 0 ~ 100 ppm | 1 ppm | 25 ppm | 35 ppm |
| Sulfur Dioxide (SO₂) | Electrochemical | 0 ~ 20 ppm | 0.1 ppm | 2 ppm | 5 ppm |
| Hydrogen (H₂) | Electrochemical | 0 ~ 1000 ppm | 1 ppm | 100 ppm | 500 ppm |
| Nitrogen Dioxide (NO₂) | Electrochemical | 0 ~ 20 ppm | 0.1 ppm | 3 ppm | 5 ppm |
| Chlorine (Cl₂) | Electrochemical | 0 ~ 20 ppm | 0.1 ppm | 0.5 ppm | 1 ppm |
| Hydrogen Fluoride (HF) | Electrochemical | 0 ~ 10 ppm | 0.1 ppm | 0.5 ppm | 1.0 ppm |
| Hydrogen Cyanide (HCN) | Electrochemical | 0 ~ 50 ppm | 0.1 ppm | 10 ppm | 20 ppm |
| Hydrogen Chloride (HCl) | Electrochemical | 0 ~ 20 ppm | 0.5 ppm | 2 ppm | 5 ppm |
| VOC (PID) | Photoionization Detector (PID) | 0 ~ 4000 ppm | 1 ppm | 50 ppm | 200 ppm |
| Nitric Oxide (NO) | Electrochemical | 0 ~ 500 ppm | 0.5 ppm | ||
| Hydrogen Peroxide (H₂O₂) | Electrochemical | 0 ~ 100 ppm | 0.1 ppm |